The SGB5-40P High Voltage DC Miniature Circuit Breaker, supplied by the China-based manufacturer Zhejiang Soutya New Energy LLC, provides 1 500 V DC circuit protection.
Key Features
• Double-breakpoint arc extinguishing structure
• UC control for stable tripping under fluctuating PV voltage
• Non-polar bidirectional protection
• 500V–1500V DC / 6–40A / 1.5kA breaking capacity
• Ideal for PV string & combiner box protection

SGB5-40P High Voltage DC Miniature Circuit Breaker, supplied by China manufacturer Zhejiang Soutya New Energy LLC, is a 1500 V DC, bidirectional and non-polarized miniature circuit breaker with 1.5 kA breaking capacity — ideal for PV, BESS and EV-charger protection.

Characteristic

  • Non-polar, bidirectional protection
  • Overload & short-circuit protection
  • Short arc, high breaking capacity 1.5 kA DC
  • 18 mm width per pole, DIN-rail mounted

CBCETÜVUKCA

Application Scenarios

The SGB5-40P delivers space-saving, safe, bidirectional protection for 1500 V DC renewable-energy systems — PV, storage, EV chargers and DC micro-grids.

1. PV DC Combiner Boxes

The 1500 V DC rating allows longer strings, cutting the number of combiner boxes; bidirectional protection handles reverse night-time currents.

2. Commercial / Residential Battery Racks

Non-polarized wiring simplifies paralleling or swapping battery modules; thermal-magnetic trip quickly isolates charge/discharge faults.

3. 150 kW+ DC Fast-Charging Stations

The 18 mm-wide DIN-rail design fits compact charger cubicles; the 1.5 kA breaking capacity secures the internal DC bus.

4. DC Micro-grids & Data-center DC Distribution

Protects 750 V / 1000 V / 1500 V DC branch circuits; B, C or D curves match various load profiles.

5. High-altitude or Outdoor Distributed PV

Operates from −30 °C to +70 °C without derating up to 2000 m altitude, suiting harsh environments.

Technical Parameters

SGB5-40P High Voltage DC Miniature Circuit Breaker — Technical Parameters
Item 1P 2P 3P 4P
Model SGB5-40P
Rated Working Voltage Ue 500 V DC 1000 V DC 1500 V DC 1500 V DC
Maximum Frame Current 40 A
Rated Current In 6 A, 10 A, 16 A, 20 A, 25 A, 32 A, 40 A
Rated Insulation Voltage Ui 1000 V DC 1500 V DC
Rated Impulse Withstand Voltage Uimp 8 kV
Tripping Characteristics B / C / D
Tripping Type Thermal-magnetic
Operational Breaking Capacity Ics 1.5 kA (DC)
Ultimate Breaking Capacity Icu 1.5 kA (DC)
Electrical Life — Actual Average Value Average 1000 operations
Electrical Life — Standard Specified Value 300 operations
Mechanical Life — Actual Average Value ≥ 15000 operations
Mechanical Life — Standard Specified Value 9700 operations
Overvoltage Category III
Pollution Degree 3
Protection Level IP40; terminals IP20
Moisture and Heat Resistance Category 2
Relative Humidity ≤ 95%
Vibration Resistance According to IEC 60068-2-6
Mechanical Impact Resistance According to IEC 60068-2-27
Wiring Capacity 2.5–35 mm²
Wiring Torque 3.0 N·m
Operating Ambient Temperature −30 °C to +70 °C
Storage Ambient Temperature −40 °C to +85 °C
Installation Method DIN 35 mm rail
Altitude ≤ 2000 m
Weight 0.13 kg / pole
Dimension — Length 108 mm
Dimension — Width 18 mm 36 mm 54 mm 72 mm
Dimension — Height Max 78 mm
Package — Pcs / Box 12 6 4 3
Package — Box / Carton 10
Package — Carton / Pallet 80
Storage Store in a well-ventilated warehouse with relative humidity not exceeding 80%, ambient temperature between −40 °C and +80 °C, free of acidic, alkaline or corrosive gases.

Appearance and Installation Dimensions

SGB5-40P high voltage DC miniature circuit breaker appearance and installation dimensions

DC Wiring Diagram

SGB5-40P DC miniature circuit breaker wiring diagram

Derating Factor

Temperature Derating Factor

Rated Operating Current Coefficient vs. Ambient Temperature (−30 ~ 15 °C)
Temperature −30 °C −25 °C −20 °C −15 °C −10 °C −5 °C 0 °C 5 °C 10 °C 15 °C
Coefficient 1.279 1.261 1.242 1.223 1.204 1.182 1.161 1.143 1.127 1.103
Rated Operating Current Coefficient vs. Ambient Temperature (20 ~ 70 °C)
Temperature 20 °C 25 °C 30 °C 40 °C 45 °C 50 °C 55 °C 60 °C 65 °C 70 °C
Coefficient 1.079 1.063 1.047 1 0.984 0.968 0.952 0.922 0.904 0.891

Altitude Derating Factor

Derating Coefficients vs. Altitude
Item 2000 m 3000 m 4000 m 5000 m
Rated Working Current Coefficient 1 0.96 0.91 0.86
Rated Working Voltage Coefficient 1 1 1 1
Rated Power Frequency Withstand Voltage Coefficient 1 0.9 0.82 0.71
Rated Impulse Withstand Voltage Coefficient 1 0.9 0.82 0.71
Rated Limit Short-circuit Breaking Capacity & Electrical Life Coefficient 1 0.82 0.7 0.6

Derating Factor for Side-by-side Installation of MCBs

Derating Coefficient vs. Number of Adjacent MCBs
No. of MCBs 1 2–3 4–5 6–8 9–10
In ≤ 25 A Coefficient 1 0.96 0.9 0.8 0.7
32 A ≤ In ≤ 63 A Coefficient 1 0.92 0.8 0.7 0.6

Accessories

MX Auxiliary Release Device — Parameters
Rated Control Voltage Us DC 24–48 V; AC 110–230 V
Maximum Tripping Time < 10 ms
Coil Resistance 5 Ω
Limit Current ≥ 1.6 A
Mechanical / Electrical Life 10000 / 4000 operations
Wiring Torque 0.8 N·m
Wiring Capability 1.0 mm² hard wire; 1.0 mm² soft wire with terminal lugs
Operating Temperature Range −30 °C to +70 °C
Environmental Conditions No explosive hazardous substances; no harmful gases or conductive dust that can corrode or damage insulation
Assembly Position To the left side of the circuit breaker
Installation Conditions DIN 35 mm standard rail mounting
Auxiliary Contact OF — Parameters
Contact Breaking Capacity AC13: Ie = 3 A, Ue = 250 V; AC15: Ie = 2 A, Ue = 250 V; DC12: Ie = 0.5 A, Ue = 110 V
Minimum Operating Voltage 5 V
Minimum Operating Current 10 mA
Rated Insulation Voltage 500 V
Rated Limited Short-circuit Current Ik 1000 A
Conventional Heating Current Ith 4 A
Mechanical / Electrical Life 10000 / 4000 operations
Wiring Torque 0.8 N·m
Wiring Capability 1.0 mm²
Number of Contacts 1 normally open, 1 normally closed
Operating Temperature Range −30 °C to +70 °C
Environmental Conditions No explosive hazardous substances; no harmful gases or conductive dust that can corrode or damage insulation
Assembly Position To the left side of the circuit breaker
Installation Conditions DIN 35 mm standard rail mounting

SGB5-40P high voltage DC miniature circuit breaker application detail

Zhejiang Soutya New Energy LLC manufacturer profile Zhejiang Soutya New Energy LLC production and quality control

Send Inquiry
Contact Info
  • Address

    East of No.148, Wei 12th Road, Economic Development Zone,Yanpan Subdistrict,Yueqing City,Wenzhou,Zhejiang Province,China

For inquiries about DC Combiner Box, Charging Pile, Circuit Breaker or price list, please leave your email to us and we will be in touch within 24 hours.