The 1000V DC Combiner Box 2 In 1 Out MCB type, supplied by Chinese manufacturer Zhejiang Soutya New Energy LLC, is an IP66-rated enclosure designed for 2-string photovoltaic systems. It provides comprehensive surge protection and overload protection on the DC side of solar installations.
▶ Configuration includes: 1 DC surge protective device (SPD), 4 DC fuse holders, and 1 DC miniature circuit breaker (MCB).
The 1000V DC Combiner Box 2 In 1 Out MCB type, supplied by China
manufacturer Zhejiang Soutya New Energy LLC, is a 1000 V DC photovoltaic
string-aggregation unit built for compact, high-performance outdoor service.
Moulded from UV-stabilised polycarbonate and sealed to IP65, the enclosure
shields internal components from dust, moisture and prolonged solar
exposure. Inside, four DC fuse holders provide over-current protection for
two input string, a class II DC surge protective device (SPD) clamps induced
transients, and a single two-pole DC miniature circuit breaker (MCB)
delivers both load-switching and short-circuit isolation. Factory-pre-wired
positive, negative and PE buses guarantee low-impedance equipotential
bonding, while the 2-in 1-out configuration streamlines cabling on small
rooftop or triple-string sub-arrays. The design offers safe, visible-break
maintenance isolation and essential string-level protection within a
space-saving, wall-mount footprint.
Technical Parameter
Configuration
DC SPD*1 Pc
DC Fuse Holder*4 Pcs
DC MCB*1 Pc
SYS5-40P/2P
SYF5-32P
SYB5-80P/4P
▶ Maximum Working Voltage: 1500VDC
▶ With illuminated indicator for clear fuse status
identification
▶ Overload and short-circuit protection
▶ Compliance Standard: IEC/EN 61643-31
▶ Rated operational voltage: 1000VDC
▶ Non-polarized, bidirectional protection for simplified
wiring
▶ Maximum Discharge Current: 40kA
▶ Fuse link specification: 10x38mm, 20A
▶ Compliance standard: IEC/EN 60947-2
Specifications
2 Input / 1 Output, 1000V DC (Configuration 2)
Input
2-circuit
Output
1-circuit
Maximum Voltage
1000V
Maximum DC Short-Circuit Current (Input)
16A
Maximum Output Current
40A
Distribution Box Parameters
Material
PC+ABS
Ingress Protection (IP) Rating
IP66
Impact Protection Rating (IK)
IK09
Dimensions (L×W×H)
GNB F01-12; L270*W220*H102mm
Cable Input Port
PG09, 2.5 - 16mm2
Cable Output Port
PG21, 2.5 - 16mm2
Environment
Operating Temperature
-20°C - +60°C
Humidity
99%
Altitude
2000m
Mounting Method
Wall-mounted
Wiring Diagram
Application scenarios
1.PV string consolidation – Small rooftop arrays
Installed beneath modules or on parapet walls, the box merges two PV strings
into a single DC output. Four fuse holders provide individual string
over-current protection, while the Class II SPD clamps induced surges from
nearby lightning activity. A front-operated MCB delivers visible-break
isolation, allowing safe lock-off during inverter maintenance or rooftop
interventions.
2.Agricultural DC feeders – Irrigation and livestock systems
Wall-mounted in pump houses or barn lofts, the unit supplies solar-generated
DC to brushless pumps and milking equipment. IP66 sealing excludes grain
dust and high-pressure wash-down water, and the integrated MCB permits rapid
shutdown before seasonal equipment checks or belt replacement.
3.Remote telecom shelters – Critical communication power
Positioned inside tower compounds, the combiner feeds DC busbars that power
radio heads and battery banks. The SPD safeguards sensitive RF electronics
against transient over-voltages, while the MCB acts as a local disconnect
for technicians performing tower earthing measurements or rectifier swaps.
Fixed within meter cupboards or attic trusses, the enclosure consolidates
two module strings for shared inverter use. Fire-retardant polycarbonate and
string-level fusing enhance safety in populated buildings, and the MCB gives
emergency responders a single labelled point to isolate the DC side during a
fire event.
5.Industrial micro-grid nodes – Backup and peak-shaving circuits
Flange-mounted on skids that couple PV with forklift chargers or PLC racks,
the box handles 15 kW of solar input. The dual-string capability matches
peak-shaving demand profiles, and the coordinated SPD + MCB pair shields
sensitive drives from both grid spikes and inverter commutation noise.
Hot Tags: 1000V DC Combiner Box 2 In 1 Out MCB type
East of No.148, Wei 12th Road, Economic Development
Zone,Yanpan Subdistrict,Yueqing City,Wenzhou,Zhejiang
Province,China
For inquiries about DC Combiner Box, Charging Pile, Circuit Breaker or price list, please leave your email to us and we will be in touch within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy