The SYM6L Residual Current Operated Circuit Breaker, supplied by China manufacturer Zhejiang Soutya New Energy LLC, provides 50 kA short-circuit breaking capacity and automatic reclosing for photovoltaic grid connected boxes and charging stations.
The SYM6L Residual Current Operated Circuit Breaker, supplied by China-based manufacturer
Zhejiang Soutya New Energy LLC, is a 400 V AC, 125-250 A thermal-magnetic
circuit breaker featuring adjustable trip settings and an 85 kA rated
ultimate short-circuit breaking capacity (50 kA rated service breaking
capacity). With a double-break contact system and positive isolation, it is
designed for reliable circuit protection in commercial switchboards, solar
AC combiner boxes, and motor feeder circuits.
Technical Parameter
Frame current Inm(A)
Pole
Rated Voltage(V)
Rated Insulation Voltage
(V)
125A
3P+N
AC400V
800V
250A
/50Hz
Rated Impulse Withstand Voltage (V)
Limit Short-circuit Breaking Capacity Icu (kA)
Running Short-circuit Breaking Capacity Ics (kA)
Executive standards
8000V
50kA
35kA
GB/T 14048.2
IEC/EN 60947-2
Application scenarios
1. 400 V PV grid-tie box
After string inverters are paralleled to the low-voltage bus, the breaker
trips on transient faults and auto-recloses within 0.5-30 s, cutting
generation losses for rooftop or car-port plants.
Used as an incoming or outgoing feeder, its 35 kA service breaking capacity
covers high fault currents in workshops; auto-reclose eliminates the need
for on-site manual reset.
3. LV outgoing circuits in package substations
Replaces standard MCCBs on the 0.4 kV side; automatic re-energisation after
a short-circuit trip shortens substation outage time and improves supply
continuity.
4. Remote PV blocks in agro-PV or fishery-PV sites
Long AC collection lines often trip on momentary earth faults or lightning;
the reclosing function saves long maintenance drives and reduces O&M
cost.
5. AC side of battery PCS
Installed between the PCS and isolation transformer, it recloses
automatically when the grid recovers from voltage dips or momentary losses,
safeguarding peak-shaving revenue.
6. Telecom towers & lighthouse micro-grids
In unattended sites the breaker recloses after mains or diesel-generator
transients, keeping the base station powered without manual inspection.
Hot Tags: Residual Current Operated Circuit Breaker
East of No.148, Wei 12th Road, Economic Development
Zone,Yanpan Subdistrict,Yueqing City,Wenzhou,Zhejiang
Province,China
For inquiries about DC Combiner Box, Charging Pile, Circuit Breaker or price list, please leave your email to us and we will be in touch within 24 hours.