The SYM6L Residual Current Operated Circuit Breaker, supplied by China manufacturer Zhejiang Soutya New Energy LLC, provides 50 kA short-circuit breaking capacity and automatic reclosing for photovoltaic grid connected boxes and charging stations.

The SYM6L Residual Current Operated Circuit Breaker, supplied by China-based manufacturer Zhejiang Soutya New Energy LLC, is a 400 V AC, 125-250 A thermal-magnetic circuit breaker featuring adjustable trip settings and an 85 kA rated ultimate short-circuit breaking capacity (50 kA rated service breaking capacity). With a double-break contact system and positive isolation, it is designed for reliable circuit protection in commercial switchboards, solar AC combiner boxes, and motor feeder circuits.

Technical Parameter

Frame current Inm(A) Pole Rated Voltage(V) Rated Insulation Voltage
(V)
125A 3P+N AC400V 800V
250A /50Hz
Rated Impulse Withstand Voltage (V) Limit Short-circuit Breaking Capacity Icu (kA) Running Short-circuit Breaking Capacity Ics (kA) Executive standards
8000V 50kA 35kA GB/T 14048.2
IEC/EN 60947-2

Application scenarios

1. 400 V PV grid-tie box

After string inverters are paralleled to the low-voltage bus, the breaker trips on transient faults and auto-recloses within 0.5-30 s, cutting generation losses for rooftop or car-port plants.

2. Industrial & commercial floor-level switchboards

Used as an incoming or outgoing feeder, its 35 kA service breaking capacity covers high fault currents in workshops; auto-reclose eliminates the need for on-site manual reset.

3. LV outgoing circuits in package substations

Replaces standard MCCBs on the 0.4 kV side; automatic re-energisation after a short-circuit trip shortens substation outage time and improves supply continuity.

4. Remote PV blocks in agro-PV or fishery-PV sites

Long AC collection lines often trip on momentary earth faults or lightning; the reclosing function saves long maintenance drives and reduces O&M cost.

5. AC side of battery PCS

Installed between the PCS and isolation transformer, it recloses automatically when the grid recovers from voltage dips or momentary losses, safeguarding peak-shaving revenue.

6. Telecom towers & lighthouse micro-grids

In unattended sites the breaker recloses after mains or diesel-generator transients, keeping the base station powered without manual inspection.

Zhejiang Soutya New Energy LLCZhejiang Soutya New Energy LLC

Hot Tags: Residual Current Operated Circuit Breaker
Send Inquiry
Contact Info
  • Address

    East of No.148, Wei 12th Road, Economic Development Zone,Yanpan Subdistrict,Yueqing City,Wenzhou,Zhejiang Province,China

For inquiries about DC Combiner Box, Charging Pile, Circuit Breaker or price list, please leave your email to us and we will be in touch within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept