The SYK18 200-4000A Knife Switch, supplied by China manufacturer Zhejiang Soutya New Energy LLC, provides reliable isolation and switching capability for low-voltage AC distribution systems.
▶ 200A and 400A use single blades.
▶ 600, 1000, and 1500A use dual blades.
▶ Standard : GB/T 14048.3,IEC/EN 60947-3
The SYK18 200-4000A Knife Switch, supplied by China-based manufacturer
Zhejiang Soutya New Energy LLC, designed with a robust construction, it
offers a high short-circuit withstand rating and safe visible break
isolation for various industrial and commercial applications.
This SYK18 low-voltage knife switch is suitable for use in distribution
boxes, control panels, and as a main disconnect switch where a clear
isolation point is required for maintenance and safety purposes. Its design
ensures easy installation and stable performance in demanding electrical
environments.
Characteristic
▶ 200A and 400A use single blades.
▶ 600, 1000, and 1500A use dual blades.
Both sides of all blades are equipped with leaf springs to achieve contact
pressure, and the blades, connecting plates, and contacts are all tin-plated
to enhance surface protection and improve the contact resistance of wire
connections.
Application scenarios
1. AC/DC Isolation in Industrial ESS
SYK18 serves as a visible-break switch after the main breaker in 0.4 kV
cabinets. After PCS shutdown, turning the handle creates a visible gap for
safe maintenance. Mechanical interlock prevents live closing. 200–1600 A
covers 100 kW–1 MW systems, no CT needed.
2. Low-Voltage Bus Section Isolation
SYK18-2000/2500/3150 A used as bus tie isolator. Double break (breaker +
knife switch) prevents misjudgment from contact welding, meeting GB/T 5226.1
requirements. Front operation saves outage time.
3. PV Combiner Box DC Isolation
Custom SYK18 with reinforced contacts for 1000 V DC systems. 200–630 A
switches per MPPT input prevent arcing after dark. Rotating operation
reduces errors. Dual break with DC MCCB meets NB/T 32004.
4. Generator Utility Isolation
Installed upstream ATS in genset applications. Physical isolation prevents
backfeed. 3150 A handles 2000 kVA systems with 50 kA/1s withstand. Lockable
handle supports LOTO procedures.
East of No.148, Wei 12th Road, Economic Development
Zone,Yanpan Subdistrict,Yueqing City,Wenzhou,Zhejiang
Province,China
For inquiries about DC Combiner Box, Charging Pile, Circuit Breaker or price list, please leave your email to us and we will be in touch within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy